← Retour à FusionSoReady · Interactive flow demonstrationFictional data · No live feed
SOREADY / EVENT OPERATING SYSTEM

Event Data Fabric — Games-Time

DEMO REFERENCE DEMO · SOURCE LOADING SIMULATION · NON CONNECTED · NON OFFICIAL connecting
REAL-TIME EVENT DIGITAL TWIN

Planned operations meet actual event reality.

Sport timing/results plus weather, safety, people, venues, mobility, IT, media and services converging into one Event Data Fabric. Time Control slows or accelerates both incoming demo events and visual animations without freezing the live view.

TIME CONTROL 1× slow ↔ fast
EXTERNAL / VENUE SOURCES
Sport · Weather · Safety · Teams · Sites · Transport · Services
FEED INGRESS EXCHANGE
Authenticate · Limit · Validate · Quarantine
EDF EVENT ROUTER
Persist · Route · Replay · Normalize
EOS
Correlate · Alert · Decide · Learn
MESSAGES / SEC0.0live ingest
EDF FEEDS—enabled
SPORT FEEDS—DEMO Selected disciplines
LIVE NOW0competition units
OPS SIGNALS0last 60 sec
CORRELATIONS0scenario events
INGEST LATENCY—simulated source → EOS
REFERENCE DATADEMOloading source manifest…
OPERATIONAL LENSES

10 feed domains · click to zoom in

Pictograms give an immediate reading of the Event Data Fabric. Each tile opens its dedicated cockpit, then each feed can be inspected individually.

● LIVE VIEW
FOCUS WALL

12 representative disciplines · continuous DT_CURRENT

All Selected disciplines come from the current Demo reference DEMO reference; live values are synthetic.

LIVEDELAYOFFICIAL
LIVE FEED INSPECTOR

Message evidence

Waiting for first ODF message…

        
OPERATIONAL SITUATION

What needs attention now?

A calm synthesis replaces the scrolling bus. Open the Event Stream only when you need the chronology.

Waiting for operational signals…
PLANNED vs ACTUAL

Operational variance radar

Click a discipline row to open its 360° view · synthetic timing values.
Sport / disciplineVenuePlannedStatusProgressΔ StartLive evidence
DEMO FULL-SCOPE SIMULATION

All Selected disciplines from current Demo reference DEMO

discipline profiles · synthetic live scoring
EDF CONTROL PLANE

Feed Control Center

Activate, isolate, inspect and simulate every feed, grouped by operational domain, before any real provider is connected.

EVENT INTELLIGENCE

EVENT-DEMO correlation scenarios

Coherent multi-feed situations that turn raw telemetry into operational context and decisions.

CORRELATION ENGINE OUTPUT

Latest correlated event

Run a scenario to see the EOS correlation output.

TARGET PIPEWORK

Secure Feed Exchange Zone + EDF Router

External feeds are treated as untrusted input. No provider, field device or public data source writes directly into the EOS core.

SOURCESTiming provider / Local weather / IF / venue / provider / NOC / VMS / IoT
→
FEED INGRESS GATEWAYTLS/mTLS · auth · WAF · allow-list · rate/size/time limits
→
ADAPTER / LANDINGraw immutable · hash · safe parser · schema · quarantine
→
EDF EVENT ROUTERNATS Event router · durable subjects · replay · backpressure
→
EOS COREcanonical model · correlation · MOC · audit · analytics
SI / NOC INGESTION

Three independent signals, one operational picture

ANIMATED
SWITCH / ROUTER / WLAN / UPSmanagement plane
SNMPv3 authPrivstate · counters · informs
Syslog/TLSevents · faults · changes
IPFIXflow volume · anomalies
READ-ONLY NOC COLLECTORno SNMP SET · no device configuration from EOS
→
EDF3 subjects · independent kill-switches · correlation
WEATHER FABRIC

National authority + European interoperability + observations

For Event area, Local weather remains the operational national authority. Regional weather alerts/Regional weather exchange provides the harmonised European CAP/EDR layer; forecast, radar and observations add anticipation and confirmation.

MULTI-SOURCE
Local weather Forecastforecast · up to +240 h
Local weather OBSmeasured conditions
Local weather RADARprecipitation / nowcast
Local weather CAPnational warning authority
Regional weather alerts / Regional weather exchangeCAP 1.2 · OGC API EDR · Europe
→
WEATHER NORMALIZERprovenance · authority · geometry · freshness · thresholds
→
EOS CORRELATIONVenue × FoP × schedule × outdoor SOP
RECEPTION SECURITY

Assume every feed can be hostile

  • Per-feed identity: mTLS/OAuth/API key; never one shared master secret.
  • Deny-by-default network rules and separate Internet, security, OT and core zones.
  • Strict content type, schema/profile and semantic validation.
  • Hard message size, rate, burst, timeout and decompression-ratio limits.
  • XXE disabled; no unsafe deserialization, eval or arbitrary callback URLs.
  • Quarantine malformed, unsigned or unexpected data; kill-switch per feed.
RESILIENCE

Cut does not mean data loss

  • ACK provider only after durable landing for push feeds.
  • At-least-once ingestion with deterministic idempotency/deduplication.
  • NATS Event router persistent streams, durable consumers and replay.
  • Pull feeds keep cursor/ETag/watermark and reconcile after reconnect.
  • Venue edge collectors spool locally and forward when WAN returns.
  • Dead-letter/quarantine queues preserve evidence instead of dropping it.
OT / SECURITY SYSTEMS

Never expose field protocols to Internet

  • BACnet, OPC UA, fire panels, lifts and power remain on venue OT networks.
  • Read-only local gateway exports a canonical subset outbound over mTLS.
  • VMS/radio/security feeds come from management gateways, not cameras/terminals directly.
  • EOS is observational by default; actuation requires a separate governed path.
MEDIA

Metadata, not heavy essence

  • Video/audio stay in ST 2110/AES67/VMS/broadcast fabrics.
  • EOS receives flow state, alarms, timestamps and recording references.
  • Photo-finish evidence is referenced and hashed; EOS does not become the homologated finish system.

Two components, not one

Feed Ingress Gateway protects and translates the boundary. EDF Event Router distributes accepted events internally. Collapsing both roles into the portal application would couple security, provider protocols and user-facing EOS logic — precisely what this architecture avoids.

ZERO-TRUST INGESTION

Security Lab — receive, distrust, validate, isolate

Security and continuity are separate planes: a message can be replayable and still be hostile. Every replay re-enters the same validation chain.

UNTRUSTED SOURCEprovider / venue / public API
→
SAS 1 · IDENTITYmTLS · OAuth/HMAC · per-feed ACL
→
SAS 2 · TECHNICALWAF · limits · safe parser · anti-XXE
→
SAS 3 · SEMANTICschema · ranges · references · sequence
→
ACCEPTEDraw hash + canonical event
QUARANTINEraw preserved · no operational publish
DATA
ACCEPTED0
QUARANTINED0
DROPPED0
ISOLATED FEEDS0
READYChoose a test above. The animation shows where the input is accepted or rejected.
CONTINUITY PLANE

Cut ≠ loss

Source→Buffer→Durable raw→Event router→Replay
  • At-least-once ingestion + deterministic idempotency.
  • ACK push only after durable acceptance policy.
  • Pull feeds retain cursor/ETag/watermark.
  • Venue edge collectors spool locally during WAN loss.
  • Replay always re-enters validation; it never bypasses security.
TRUST PLANE

Replayable ≠ trusted

Replay→Identity→Parser→Schema→PASS / Q
  • Credential/certificate scoped per feed and environment.
  • Hard quotas prevent resource exhaustion and decompression bombs.
  • Strict parser isolation protects the portal from malicious payloads.
  • Quarantine is outside the operational bus.
  • Kill-switch isolates one feed without stopping the EDF.
OT / LIFE SAFETY

Outbound-only, read-only

FIRE / BMS / UPS / LIFT→EDGE COLLECTOR→ mTLS OUTFIG× EOS COMMANDS
  • No Internet ingress to BACnet/OPC/fire/lift devices.
  • EOS remains outside fire, access and power safety/control loops.
  • Actuation, if ever needed, is a separate governed architecture.
SOC / FORENSICS

Every decision leaves evidence

  • Source identity + native message ID + timestamps.
  • Raw immutable object + SHA-256.
  • Adapter version, schema/rule version and canonical event ID.
  • PASS / QUARANTINE / DROP reason codes.
  • Security telemetry goes to SIEM/SOC; EOS receives only operational impact.
NETWORK ZONES

One-way trust progression

INTERNET / PROVIDER
→
FEZ / DMZ
→
EDF BROKER
→
EOS CORE
VENUE OT / SECURITY
→ outbound mTLS →
FEZ EDGE INGRESS
→
EDF
NO REVERSE CONTROL PATH